Ministro Victor Konder
Ministro Victor Konder (SBNF) serves Navegantes, Brazil. This is a mid-sized airport with 1 runway (07/25). Field elevation is 18 ft AMSL. Data on this page is maintained by the aviation community — contribute to keep it accurate.
Section Breakdown
See a next to a field? Click it to confirm the info is still correct. Recently verified Outdated — please verify
Basic Airport Information
- ICAO: SBNF
- Name: Ministro Victor Konder
- Type: medium_airport
- Category: International
- Latitude: -26.879431
- Longitude: -48.650978
- Elevation: 18 ft
- Country: Brazil
- Municipality: Navegantes
- IATA Code: N/A
- FAA Code: N/A
- FIR: SBCW
- Timezone: America/Sao_Paulo
- Distance from City: 1.2 km
- VFR: Yes
- IFR: Yes
Runways
Runway 07/25
- Designation: 07/25
- Dimensions: 5581 X 148
- Surface: ASPH
- PCN: 52/F/B/X/T
- Lighting: N/A
- NAVAIDs: N/A
- Approach Types: ILS CAT I, RNAV (GPS), VOR
- Remarks: N/A
Frequencies
- Tower: 118.200 MHz
- Ground: N/A
- Operations: N/A
- Traffic/Approach: 119.500 MHz
- ATIS: 127.625 MHz
Operation Hours
- Open: N/A
- Close: N/A
- Extra Hours On Request: Yes
- Remarks: OPR TIME IN UTC -3 AD service hours 0800-0245 ACFT in APCH for RWY 07, OBS crane and passage of ships on the river Itajaí-Açu, APRX 1000M from the runway end. OBS OBST NEG LGTD (Crane) DIST 1640M from THR 07, 26 53 49S/048 39 56W, AZM 206DEG, ELEV 370FT . OBS OBST NEG LGTD (Crane) DIST 2000M from THR 07, 26 54 06S/048 39 39W, AZM 187DEG, ELEV 370FT. Crane and passage of ships on the Itajaí-Açu River, APRX 1000M from THR 07. RWY 07 and RWY 25 last 90M CLSD for LDG/TKOF due to provision of RESA The AD can be regularly used by aircraft compatible with RCD 4C or lower. PRB simultaneous operation of ACFT on the TWY of the ACFT PRKG courtyard with the OPS of LDG and TKOF of ACFT of reference code 3 or 4 on RWY 07/25 under Instrument Meteorological Conditions (IMC) PRB simultaneous push-back operation with LDG and TKOF OPS of ACFT of reference code 3 or 4 on RWY 07/25 in Instrument Meteorological Conditions (IMC) 180DEG turn of ACFT the size of Fokker 100, Boeing 737, or larger, only on the THR. Compulsory prior AUTH from the concessionaire with at least 02 (two) HR in advance to the operation, upon request through the WebApp-CCR AVG by the link ga.ccraeroportos.com.br when: 01 - ACFT needing patio reservation; 02 - ACFT of international registration; 03 - ACFT of Brazilian registration and more than one owner/operator registered in the Brazilian Aeronautical Registry (RAB); 04 - ACFT of Brazilian registration, without aircraft/financial registration in the WebApp-CCR AVG or that needs updating, even without intention of using the patio; 05 - Exempt ACFT, in experimental or instruction flight, in cases where the aircraft's registry category in the RAB is not listed as PRIVATE, INSTRUCTION or EXPERIMENTAL. -The Airport Operations Center (APOC) will analyze the request and return with the status through the WebApp- CCR AVG. When necessary, adjustments in the schedule will be requested, which should be regularized at least 30 MIN before the operation, otherwise the request will be canceled. -For questions or assistance, consult the communication channels on the website www.ccraeroportos.com.br/clientes-aeroportuarios. -In case of contingency, contact the airport via email: apoc.nvt@grupoccr.com.br. OBS ACFT in instructional flight near the AD Mandatory use of push back for ACFT above 20t, in the exit PROC of PRKG. Type of operation by runway/headland: Headland 07: Day/Night VFR and Day/Night Non-precision IFR; Headland 25: Day/Night VFR and Day/Night Non-precision IFR; OBS concentration of birds on the sides of RWY 07/25 and near THR 07. Identified species are Tapicuru (Phimosus infuscatus) and Quero-quero (Vanellus chilensis). SER referring to the immigration and customs formalities in servicing INTL flights, except for regular and charter flights previously authorized by ANAC, should be requested 48HR in advance, sending the general declaration (GENDEC) to the email apoc.nvt@grupoccr.com.br. Changes in schedules and delays should be informed 4 hours in advance due to the Federal Public Authorities that operate on demand, otherwise the request will be cancelled. Positions of ACFT 2,3 and 4 RTO using EQPT Air Starter Unit (ASU), Ground Power Unit (GPU) and Low Pressure Unit (LPU) due to noise. ACFT that need to use only O/R through the TEL (47) 3342-9205 (COA) with MNM 30 MIN advance from the LDG. Engine check AUTH only between 1000-2300. Incidence of kites in THR 07, THR 25 and in the TFC circuit, mainly in the months of JAN, FEB, JUL and DEC. MEHT: 50FT MEHT: 53FT Self-service (DLY 0900-0300) - O/R: Through the TEL (47) 3342-9205 and (47) 3342- 9211. OPR Petrobrás and Shell. (DLY 0910-0300) (DLY 0845-0245) PRB the transmission of PVS via radiotelephony, from the ground, to the ATS bodies. PLN AFIL from ACFT taking off from an AD devoid of AIS Room located in the projection of the BDRY of the TMA Florianópolis will not be accepted by APP Florianópolis. (DLY 0900-0245) OPR NAV Brazil Emergency AIS provided exclusively by the internet and the Aeronautical Information Center - AIR NAVIGATION MANAGEMENT CENTER (C-AIS CGNA), Reception of PLN and update MSG TEL: (21) 2174-7510. User registration in the Integrated Air Movement Management System (SIGMA) (21) 2101-6680.
Contacts
- AIS Tel: N/A
- ARO Tel: N/A
- MET Tel: N/A
- Admin Tel: N/A
- Health Tel: N/A
- Police Tel: N/A
- Authorities Tel: N/A
- Website: N/A
- Remarks: N/A
Slots / PPR
- Slot Required: No
- PPR Required: No
- PPR Contact: N/A
- Remarks: N/A
Fees
- Landing Fee: BRL 18 per 1,000 kg MTOW
- Parking Fee: BRL 9 per 1,000 kg per hour
- Handling Mandatory: No
- Currency: BRL
- Remarks: Standard airport fees apply at SBNF.
Fuel Information
- Fuel Type: Jet A-1
- Price/L: N/A
- Last Updated: 2026-02-18
- Remarks: Standard Jet A-1 available at SBNF.
Immigration
- Port of Entry: Yes
- GENDEC Required: Yes
- GAR Required: No
- Remarks: Port of entry. eAPIS required. Navegantes, Santa Catarina.
Restrictions
- Curfew Start: N/A
- Curfew End: N/A
- Noise Chapter Min: N/A
- Remarks: Southern Brazil coast. Alternative to Florianopolis.
Alternates
SBFL
- ICAO: SBFL
- Name: Hercílio Luz
- Distance (NM): 47.8
- Has IFR: Yes
- Port of Entry: Yes
- Immigration Remarks: International port of entry. eAPIS required. Florianopolis, island city.
SBCT
- ICAO: SBCT
- Name: Afonso Pena
- Distance (NM): 85.9
- Has IFR: Yes
- Port of Entry: Yes
- Immigration Remarks: International port of entry. eAPIS required. Curitiba, Parana state capital. Full FIS.
Airport Services
No services listed for this airport yet.
Are you a service provider? Register here to appear in this airport's listing.
Brazil Permit Requirements
- Overflight Permit: No
- Landing Permit: Conditional
- Overflight Lead Time: Notification only (no advance time specified for overflight-only; 24 hours recommended)
- Landing Lead Time: 24 hours (AVANAC for multi-airport); Part 135 charter: allow 5+ business days
Private/GA flights need ANAC authorization and DECEA flight plan approval. Recommend 5 days lead time.
Nearby Airports
Airport History
Discover the key milestones and historical events that shaped Ministro Victor Konder. Our community-powered timeline traces this airport's journey from its origins to the present day.
Explore HistoryFrequently Asked Questions
- What is the tower frequency at SBNF?
- The tower frequency at Ministro Victor Konder is 118.2 MHz.
- What fuel is available at SBNF?
- Ministro Victor Konder offers Jet A-1.
- Does SBNF require landing permits?
- Yes, landing permits are required for Ministro Victor Konder (Brazil).